Remodelling, Optimization and Characterization of Columns for Hydrogen Chloride and Sulphur Dioxide Absorption in Exhaust Air

Authors

  • Daniel Mesitschek
  • Ennio Vanoli

DOI:

https://doi.org/10.2533/chimia.2009.223

Keywords:

Absorption, Exhaust air purification, Htu-ntu model, Hydrogen chloride, Packings

Abstract

Hydrogen chloride and sulphur dioxide are gaseous by-products of chloridization processes that employ thionyl chloride. Absorption would be a feasible method to clean the rich gas stream. Two serial connectable absorption columns were equipped with the latest generation of packings to effect product recovery. Therefore, several tests concerning the baffle properties had to be performed. In the first experimental section, the hydraulic parameters pressure drop and hold-up were investigated. The hold up value range of the new baffles Raschig Super Ring (RSR) and Raschig Super Pak (RSP) was clearly below that of the former installed packing, Raschig Ring (RR). However, due to the low maximal flow rate, the range of stagnation and flooding could not be measured. The maximal measured pressure drop value was, for RR, only 0.3 mbar/m, which is very low compared to the measurement error. Batch experiments, where the waste gases were produced by reaction of thionyl chloride in water, showed that for the steady state determination of the separation steps it is advisable to use just one column in simplex mode with a defined gas supply by a gas cylinder. The HTU determination for RSR and a HCl/H2O system delivered a value of HTUHCl,OG = 0.14 ± 0.01 m with a variation coefficient of 24.2%.

Downloads

Published

2009-04-29

How to Cite